Offerings
|
Technical Specification
|
Description
|
Biosafety Cabinet Validation
|
Hepa Filter Integrity Test For 2 HEPA filters
Inflow Velocity Test For 9 Samples
Downflow Velocity Test For 8 Samples
Particle Count Test For 5 locations
Air Flow Pattern Test For one test
Noise Level Test For one test
Lux Level Tests For one test
|
Hepa Filter Integrity Test For 2 HEPA filters using Aerosol Photometer - (TEC Services PH-5)
Inflow Velocity Test For 9 Samples using Anemometer (TSI - 9545-A-5725)
Downflow Velocity Test For 8 Samples using Anemometer (TSI - 9545-A-5725)
Particle Count Test For 5 locations using Particle Counter - (TSI - 9350-03)
Air Flow Pattern Test For one test using Air Flow Pattern Tester - (TVSPL - FPT 500)
Noise Level Test For one test using Noise Level Meter - (Lutron-SL-4010)
Lux Level Tests For one test using Lux Meter - (Kusam Meco)
|
Cleanroom Validation
|
Air Balancing (Supply Air Terminal) Per HEPA filter
Pressure Balancing (Return Air Terminal) Per Return Air Riser
HEPA Filter Integrity/ Leakage Test per HEPA filter
Non-Viable Particle Count per Location
Room Recovery Test per Location
Temp. and RH Mapping for 24Hrs for 10 locations Min. 10 locations
Airflow Pattern Test (Flow Pattern at SA and RA Terminal) per HEPA filter
Total AHU Balancing Per AHU
|
"Air Balancing (Supply Air Terminal) Per HEPA filter
Pressure Balancing (Return Air Terminal) Per Return Air Riser using Anemometer (TSI - 9545-A-5725)- Digital Manometer (TSI - 8380)
HEPA Filter Integrity/ Leakage Test per HEPA filter using Aerosol Photometer - (TEC Services PH-5)
Non-Viable Particle Count per Location using Particle Counter - (TSI - 9350-03)
Room Recovery Test per Location using Particle Counter - (TSI - 9350-03)
Temp. and RH Mapping for 24Hrs for 10 locations Min. 10 locations Using Data Loggers
Airflow Pattern Test (Flow Pattern at SA and RA Terminal) per HEPA filter using Air Flow Pattern Tester - (TVSPL - FPT 500)
Total AHU Balancing Per AHU
|
Laminar Air Flow and Reverse LAF Validation
|
Air Velocity Test / ACPH Calculation For 4 HEPA filters
Hepa Filter Integrity Test For 4 HEPA filters
Particle Count Test For 2 locations
Air Flow Pattern Test For one test
Recovery Test Per Location
|
Air Velocity Test / ACPH Calculation For 4 HEPA filters using
Anemometer (TSI - 9545-A-5725)
Hepa Filter Integrity Test For 4 HEPA filters using
Aerosol Photometer - (TEC Services PH-5)
Particle Count Test For 2 locations using
Particle Counter - (TSI - 9350-03)
Air Flow Pattern Test For one test using
Air Flow Pattern Tester - (TVSPL - FPT 500)
Recovery Test Per Location using
Particle Counter - (TSI - 9350-03)
|
Operation Theater Validation
|
Air Velocity Test / ACPH Calculation Per HEPA filter
Hepa Filter Integrity Test Per HEPA filter
Pressure Balancing Per Return Air Riser
Particle Count Test per Location
Recovery Test per Location
Air Flow Pattern Test Per Return/supply Air terminal
Temp. and RH Mapping for 24Hrs for 6 locations Min. 10 locations
|
Air Velocity Test / ACPH Calculation Per HEPA filter using Anemometer (TSI - 9545-A-5725)- Air capture hood (TSI-8380).
Hepa Filter Integrity Test Per HEPA filter using Aerosol Photometer - (TEC Services PH-5)
Pressure Balancing Per Return Air Riser using Anemometer (TSI - 9545-A-5725)- Digital Manometer (TSI - 8380)
Particle Count Test per Location using Particle Counter - (TSI - 9350-03)
Recovery Test per Location using Particle Counter - (TSI - 9350-03)
Air Flow Pattern Test Per Return/supply Air terminal using Air Flow Pattern Tester - (TVSPL - FPT 500)
Temp. and RH Mapping for 24Hrs for 6 locations Min. 10 locations Using Data Loggers
|
Positive Air Pressure Module Validation
|
Air Velocity Test / ACPH Calculation (01 Nos) Air Velocity Test / ACPH Calculation (01 Nos) For one HEPA filter
Hepa Filter Integrity Test (01 Nos) For one HEPA filter
Particle Count Test (only if unit is connected to Cleanroom) (02 Nos) For 2 locations
Flow Pattern Test (only if unit is connected to Cleanroom) For one HEPA filter
Noise Level Test For one test for one HEPA filter
|
Air Velocity Test / ACPH Calculation (01 Nos) For one HEPA filter using Anemometer (TSI - 9545-A-5725)
Hepa Filter Integrity Test (01 Nos) For one HEPA filter using Aerosol Photometer - (TEC Services PH-5)
Particle Count Test (only if unit is connected to Cleanroom) (02 Nos) For 2 locations using Particle Counter - (TSI - 9350-03)
Flow Pattern Test (only if unit is connected to Cleanroom) For one HEPA filter using Air Flow Pattern Tester - (TVSPL - FPT 500)
Noise Level Test For one test using Lux Meter - (Kusam Meco)
|