EMI and EMC Calibration
  • facebook
  • twitter
  • linkedIn
  • whatsapp
  • email

EMI/EMC Calibration

EMI/EMC determines whether a device or system will create an electromagnetic disturbance and interfere with the operations of other devices. When you have properly calibrated testing equipment, you are assured of accurate measurements related to the electromagnetic compatibility of a product or system. The equipment that measures or generates electromagnetic fields must be calibrated periodically to verify proper operations.

group_work View Our Offerings

    Offerings

    Technical Specification

    Description

    Combination Wave
     Surge Generator Calibration

    Voltage Amplitude: (± 0.5 kV to ± 20 kV)
     Voltage Front Time: 1.2 µs to 10 µs
    Voltage Pulse Width: 50 µs to 700 µs
    Current Amplitude: (± 0.25 kA to ± 3.0 kA)
     Current Front Time: 8 µs
    Current Pulse Width: 20 µs

    Combination Wave Surge (Generator HV o/p and CDN o/p)
     Parameters: Voltage Amplitude, Pulse Front Time, Pulse width, Current,
    Amplitude, Current Front Time, Current Pulse Width

    Coupling /
     Decoupling
     Network Calibration

    Voltage Division Factor: 1dB to 60dB (9kHz to 300MHz)
    Decoupling: 9kHz to 300MHz
    Common Mode Impedance: 1 Ω to 300 Ω

    Voltage division factor, impedance, decoupling of common mode disturbance

    Damped Oscillatory
     Wave Generator Calibration

    Calibration for all range

    Voltage Amplitude, Pulse Rise Time, Oscillation Period, Repetition rate

    EFT Test generator Calibration

    Pulse Amplitude: (± 125 V to ± 5 kV)
     Rise Time: 5 ns
    Pulse Width: 50 ns
    Repetition Frequency: 5 kHz (200 µs)
     Burst Duration: 0.75 ms to 15 ms
    Burst Period: 300 ms

    Electrical Fast Transient (Single/ Three Phase, 5KHz-100KHz); Pulse Amplitude, Pulse
     Rise Time, Pulse width, Repetition Rate, Burst Duration, Burst Period

    EM Clamp Calibration

    Coupling Factor/ Coupling Loss: 9 kHz to 20 GHz

    Coupling factor, Coupling loss

    EMI Receiver Calibration

    Return Loss (VSWR): 9 kHz to 20 GHz (1 dB to 46 dB)
     Display Error of Detectors with Pulses: (Peak, Quasi-Peak, RMS-Average,                          
    BAND A, PRF: Isolated, 1Hz to 100Hz/BAND B, PRF: Isolated, 1Hz to 1 kHz
     BAND C/D, PRF: Isolated, 1Hz to 1 kHz/ Display Error of Detectors with Sinusoidal Signals: 9 kHz to 18 GHz

    VSWR, Display Error of detectors-pulses (Peak, Quasipeak,
    RMS, Average) Display error of detectors-sinusoidal signals

    ESD Generator Calibration

    Contact Discharge current:
     First Peak current Ipk and Current at tns: 15 A to 112.5 A (± 2 kV ± 30 kV)
     Rise/Fall Time: 0.6 ns to 1 ns (up to 30kV)
     Air discharge DC voltage: ±(2-30kV)

    First Peak Current, Rise time, Current at t1 and t2

    LISN Calibration

    Insertion Loss /RF Attenuation: 0dB to 60dB (9kHz to 1GHz)
    Phase Angle: -90° to 90 ° (9kHz to 600MHz)
     Isolation: 2dB to 60dB (9kHz to 300MHz)
    Impedance: 1 W to 300 W (9kHz to 300MHz)

    Single/ Three Phase/DC; Parameters: Insertion loss, Impedance, Isolation, Phase angle

    Pre-Amplifier Calibration

    Gain: 9 kHz to 20 GHz (10 dB to 70 dB), Return Loss VSWR 9 kHz to 20 GHz

    Gain, Return Loss, VSWR

    Ring Wave
     Generator Calibration

    Voltage Amplitude: (± 0.5 kV to ± 6 kV)
     Front Time: 0.5 µs
    Oscillation Frequency: 100 kHz
    Current Amplitude: 20A to 135A  
    Current Rise Time: <= 1 µs

    Voltage Amplitude, Pulse Rise Time, Oscillation Period, Current
     Amplitude, Current Rise Time

    Voltage Dips Calibration

    Output Voltage at no load: 0 % to 100 %   
    Dips / Interruption Time: 10 ms to 5 s

    Output Voltage at no load, Dips/ interruption Time

Key Highlights
arrow_downward
Support
arrow_downward
Enquiry
arrow_downward

Thank You!

Certification
arrow_downward
Certification Icon For Calibration Services
The Value of Ideas

Lawkim's strong emphasis on generating world class products, innovative ideas and quality product services, has gained global recognition over the past few decades. Our work culture and professional approach towards work have helped us become proud recipients of many awards.

Read more

Achievements
arrow_downward
New Initiatives
arrow_downward
Electromechanical Linear Actuators Icon
Electromechanical Linear Actuators

Read more

Solutions For Auto Sector Icon
Solutions for Auto Sector

Read more

Automated Guided Vehicle(Agv) Icon
Automated Guided Vehicle (AGV)

Read more

Air Handling Solutions Icon
Air Handling Solutions

Read more

Best Practices
arrow_downward
Lawkin Recycling Policy Icon
Lawkim Recycling Policy

We master a whole spectrum of software Electronic waste (E-waste) comprises of waste electrical/electronic goods which are not fit for their originally intended use. These outdated/obsolete electrical motors found in appliances, equipment and industries can become hazardous if not discarded properly.

Read more

Safety Icon
Safety Everywhere for Everyone

At Lawkim, safety of employees, assets and the plant is of prime importance. That is why there is a lot of emphasis on following safe working practices. The 11 best practices in safety have enabled Lawkim to surpass 2000 safe working days. Lawkim has been recognised to have the safest manufacturing shop in India.The National Safety Council of India has awarded Lawkim for its safe practices repeatedly.

Read more

Tpm For Operational Excellence Icon
TPM

At Lawkim, safety of employees, assets and the plant is of prime importance. That is why there is a lot of emphasis on following safe working practices. The 11 best practices in safety have enabled Lawkim to surpass 2000 safe working days. Lawkim has been recognised to have the safest manufacturing shop in India. The National Safety Council of India has awarded Lawkim for its safe practices repeatedly.

Read more

Six-Sigma Icon
Six Sigma

Lawkim has built an impressive body of in-house experience in implementing six sigma across its various levels of operation and businesses.We have created, translated and then trained our workmen at the shop-floor level in Hindi and Marathi in modules developed in-house a completely unique experience that gives us the ability and the cutting-edge to successfully implement Six Sigma at any level of an organization. Hands-on experience that can enhance your performance at either managerial or the shop-floor level.

Read more

Kaizen as Best Practice Icon
Kaizen

We practice Kaizen as one of the tools to pursue our Vision, Mission & Values.Every employee at Lawkim is engaged with this process to serve our customers better Year on Year Improvement in Kaizen Performance

Read more

Innovation as Best Practice Icon
Innovation

At Lawkim, we encourage each team member to think differently. For this, training and workshops are regularly conducted internally as well as externally with the help of experts. This inspires people to be creative and think of new and different ways of doing things.

Read more

Chaitanya - Lawkim Newsletter Icon
Chaitanya - Lawkim Newsletter

This award was in recogni5on of the efforts and contribu5ons made by the Team and cerfies Lawkim's achievement of Excellence in Opera5ons due to its implementaion of improvement ac5vi5es under Excellence in Operasonal Technology which has brought remarkable results in business, opera5onal parameters and cultural change among employees' behaviour towards improvement.

Read more

Milestones
arrow_downward
Milestone Icon For Calibration Services
The Journey so far..

Read more

In the News
compare Compare Now